ClearShield’s Fire Attenuation Screens have been designed for applications to satisfy the requirements of AS1530.4-2014.
ClearShield’s Fire Attenuation Screens are an economical alternative to conventional drenching (sprinkler) systems, and they also offer a high level of security.
ClearShield Australia contracted the services of Warrington Fire Research Australia to test the ClearShield’s Fire Attenuation Screen and when tested, achieved a reduction of radiant heat of 52.3kW/m2 when exposed to Boundary* conditions (80kW/m2). That’s a massive 65% Attenuation of heat in the worst possible conditions (as indicated in the NCC)
* Clause B7.4.4 in AS1530.4(2014) specifies that if the opening to be protected is on the boundary of a property then the testing should be conducted at 80kW/m2
Grade | 6063-T6 |
Coating | Anodised – min 15um to AS1213- |
Powdercoating – Chromate Pre-treatment and powdercoated to AS3715-2002 | |
Warranty | As per Coating Selection |
Grade: | T304-2b |
Finish: | Satin Black Powder Coated |
Warranty: | 15 Years, subject to adhering to the recommended cleaning schedule |
Coating: | Powdercoating – Oxsilane Chrome Free Pre-treatment and powdercoated to AS3715-2002 |
Open Area: | 39%-41% |
Dimensions: | Domestic Grade Ø 2mm Round Holes, 60° Staggered Pitch, 3mm Spacings, 1.0mm Thick |
Standard | Date of test | Test No. | Details | Result |
---|---|---|---|---|
AS1530.2014 | 28/10/2021 | FRT210115 | Test of CS Screen over 130mins exposed to 80kW/m² | AVG Transmitted Radiation 27kW/m^{2}, AVG Blocked Irradiance 65% |
Need more information about our Fire Attenuation Screens? Call 02 4721 5241
Contact Information
Phone: 02 4721 5241
Email: stained@tpg.com.au
Showroom:
3a, 55-61 York Rd, Jamisontown NSW 2750
Business Hours
Mon - Fri 9:00 am - 5:00 pm
Sat – Sun Closed
Certifications: https://nssa.org.au/
Security License: 103175
ABN: 52 108 602 731